• Home
    • About Us
    • Acceptable Use Policy
    • Afore Factory Warranty
    • All builder items
    • Code of Practice
    • Contact
    • Customer Support Ticket
    • Customer Support Ticket Listing
    • Inverters
    • Logout
    • Lost Password
    • Monitoring
    • My Account
      • Change Password
      • Edit My Address
      • View Order
    • New Homepage
    • News
      • News – Right Sidebar
      • News-Left Sidebar
    • Pages
      • Elements
      • Shortcodes
    • Photo Gallery
    • Portfolio
    • Privacy Policy
    • Rooms
    • Sample Page
    • SEND REQUEST FOR WARRANTY
    • Shop
    • Terms and Conditions
    • Terms of Website Use
    • Installation Check List
    • AforeUK Fault Report Form
    • PDF Downloads
    • G83-2 Certificate of Compliance
    • Events
      • Events Calendar
      • Events List
    • Home Resort
    • Home Spa
    • Cart
    • Checkout
      • Checkout → Pay
      • Order Received
    • Contact Us
    • Home FlexSlider
    • Home Revolution slider

Main Navigation
  • Home
  • Inverters
  • Monitoring
  • PDF Downloads
  • News
  • Contact

Monitoring

Monitoring your PV Solar inverters ‘All Day & Every Day‘


You can log into your monitoring account – here>>

PDF USER MANUAL – here>>


 User Manual for Web Monitor HMI-901 Remote Configuration

remote-monitoring-device

Version:UM02EN-140306

 

  1. Installation

Web monitorHMI-901 should be installed at least 20cm away from the inverter, or the signal will decrease. Screw the monitor back or stick with adhesive.

  1. Wiring

2.1  Start wiring

1)        Disconnect the inverter from both AC and DC supplies

2)        Loosen the screws and Open the waterproof cover

(picture 2-1 and 2-2)

remote-monitoring-01

 

3)        Put the communication wire through the waterproof connector.( picture 2-4)

4)        Connect the wires one by one according to the wire colors and the definition chart, and ensure that all terminals are tight and sound. ( picture 2-4)

*Definition of different wire (picture2-3):

Colour Red Yellow White Black
Definition +5V 485A 485B GND
remote-monitoring-02

image 2-3

 

5)        Plug in the Green communication socket back into the inverter. (picture 2-5)

remote-monitoring-03

 

6)        Close the waterproof cover, tighten the screws and the waterproof connector.(Picture 2-6)


remote-monitoring-04

image 2-6

Notice: Please do not mistakenly connect the red and black wire in the communication port, otherwise the monitoring module might be damaged.

3      Wireless portal configuration

3.1  Make sure the inverter is up and running and generating before configuration.

3.2  Using a laptop, cell phone or tablet PC, open the WIFI/WLAN interface on your device to search for the WIFI signal of the monitor, (your laptop or your cell phone might be already connected with your existing home/office wifi signal, please disconnect with it first if there is any), the WIFI signal name will be like ”Afore_xxxxxx”, Picture 3-1)

3.3  Notice: No password is needed to connect to the Afore network.

remote-monitoring-05

image 3-1

3.4   Connect to the Afore_xxxxxx WIFI signal

3.5  Open up the internet browser on your device and locate the address bar

3.6  In the address bar, type 11.11.11.1 and press enter. This will bring up a new interface (Picture3-2)

3.7  Both the user’s name and password are “admin”

remote-monitoring-06

image 3-2

3.4 Click “confirm/OK ” and move into next interface, copy and paste the Serial number “65……c8” and save it in a file or write down in the box below, this number will be useful when registering the monitor the Afore website later. (Picture 3-3)

Note: This SN number here is the web monitor’s serial number, has nothing to do with the inverter SN number.

remote-monitoring-07

image 3-3

 

3.5  Click Find AP,

3.6  Open the Scan interface, and it will automatically search for all wireless routers in the surrounding area.

3.7  Select your home or office Network and connect.

3.8  In the next interface (Picture 3-3), input the password to your existing router in the Key column (Picture 3-3). Please make sure the signal strength is at least 30% (Picture 3-4), otherwise the communication will affected.

remote-monitoring-08

image 3-4

 

3.9  Click “Save and reboot “to save this configuration。

3.10  Wait for 5 seconds to complete the process.

3.11  Either press refresh or ‘F5’ to reload the page.

3.12  Move onto the account register section.

remote-monitoring-09

image 3-5

 

3.13  If Current Local IP; Current Netmask; Current Gateway IP; Current DNS Server all displays specific data rather than “0”, it means the monitor device has successfully obtained an IP address and can work normally.

3.14  If the interface shows as Picture 3-6, it means the monitor device failed to connect with the router or the internet connection is not normal. When this happens, user should check if the password of the router is correct or if the wifi signal is too weak.

remote-monitoring-010

image 3-6

 

It is also possible that the user’s router has got a Static IP Address,

The user can use the similar method to set up by clicking “IP Address”, enter the IP address setting interface.

Close DHCP Select by choosing Disable, then input the Static IP address, Net Mask, Gateway IP and DNS.

Then Save the settings.

Wait for 2 minutes and retype 11.11.11.1 in the web browser and enter, then click IP Address and check. If Current Local IP; Current Netmask; Current Gateway IP; Current DNS Server all displays specific data rather than “0”, means the setting is successful. If not, please confirm if the router allows wireless device to be connected.

(This check function haven’t been implemented for the current stock before 23rd April).

If the router needs MAC address, please get it from the previous copying SN step. 


 

4       Account register

4.1  Using your laptop or PC, disconnect from “Afore_xxxx” wifi and connect onto your home/office wifi network.

4.2  Visit Registration Site & Click SIGN UP.

4.3  This will bring up the “Afore Energy Remote Monitoring” log in interface(Picture 4-1),

4.4  Select your desired language in the bottom right corner, click “Sign up”

4.5   Then interface like Picture 4-2 shows. Input user’s name, password, register email address and the SN number which had been saved in Chapter 3.3, click sign up to confirm and complete the registration.

remote-monitoring-011

remote-monitoring-012

4.1  After registration is completed,

4.2  Login with YOUR user name and password, select your own language in the upper right corner if necessary. This setting will be saved to this account number, when you log in next time, you wont need to set this up again.


 

5        User’s instructions

5.1  Log in

Log into the monitoring system with your registered user’s name and password, the system will automatically generate a PV system monitoring site, called “my sites” (Picture 5-1)

remote-monitoring-013

image 5-1

Click “view”, to view the PV system’s operational data which will now be displayed. (Picture 5-2)

remote-monitoring-014

image 5-2

 

5.2       Edit, add sites and add inverters by users

In Afore Energy Remote Monitoring System, users not only can view their own sites, but can also edit.

Click “Edit”, move to the interface shown as Picture 5-3, users could edit content such as PV system name, location, local feed-in tariff, PV system introduction, and can also select PV system location on the map.

remote-monitoring-015

image 5-3

 

The “Sort No” in the bottom shows the current PV systems position sequence, the smaller number rank higher position of the list. Input the relevant information and save the settings to complete the PV system new site adding.

If users need to monitor more than one PV system, click “+New site” the similar interface of editing site shows, also type in name, location information etc. The only difference is users need to input the SN number of the inverter installed in this PV system (Picture 5-4)

remote-monitoring-016

image 5-4

If users need to add more than one inverter in the monitoring system, click “Inverters” in the left column, interface shown as Picture 5-5. Users could edit current inverter or add new inverters with similar steps. Here we will introduce “Add New Inverter” as an example

remote-monitoring-017

image 5-5

Click “Add New Inverter”, type in relevant information and click “save to” complete the adding. (Picture 5-6)

remote-monitoring-018

image 5-6

 

5.3      User’s information setting

For Users to edit their own account information, click “Settings” in the left column (Picture 5-7).

remote-monitoring-019

image 5-7

5.4      PV system management

Afore Energy Remote Monitoring System provides abundant functions of PV system monitoring and management.

5.4.1        Real-time Display

Real-time display provides users with basic real-time working data information of the PV system, and enable the users to quickly view their own PV systems working status. Select a site, click “view”, and choose “Real-time display”(Picture 5-8)

remote-monitoring-020

image 5-8

 

5.4.2        Alarm Record

In the Alarm Record page, users could check the relevant event list for each individual inverter, with additional info regarding fault codes and the time that the fault occurred. (Picture 5-9)

remote-monitoring-021

image 5-9

5.4.3        History Record

In History Record page, users could check the curves of historical data and could also check the specified time period of certain operation parameters, such as “Power now” (Picture 5-10)

remote-monitoring-022

image 5-10

 

5.4.4        Report Analysis

In the Report Analysis page, users could check the PV system daily, monthly, and yearly report.

remote-monitoring-023

image 5-11

 

5.4.5        Auto-sending Settings

In this page, users could set faulty report automatic sending by day, week and month. See Picture 5-12, select the “on” option of the specific report.

Please use help@aforeuk.com for the alarm notification only

then Save the settings, this will allow any faults that occur to be monitored and resolved by AforeUK.

remote-monitoring-024

image 5-1

 <<END>>

If you require any further assistance, please use our Contact Form, or call us direct on 01283 845039

 

Legal Matters

  • Acceptable Use Policy
  • Code of Practice
  • Privacy Policy
  • Terms and Conditions
  • Terms of Website Use

Documentation

  • Installation Check List
  • AforeUK Fault Report Form
  • Afore Factory Warranty
  • PDF Downloads
  • G83-2 Certificate of Compliance

Support Tickets

  • Customer Support Ticket
  • Customer Support Ticket Listing

Tickets

Global stats :
  • Tickets created : 7
  • Tickets closed : 7
Copyright © 2016 All Rights Reserved. AFOREUK LTD | Sitemap
Powered by intelHUB
  • Stay Connected
  • Twitter
  • Facebook
  • Google Plus
  • Skype